Water-Cooled Light Weather Fastness Tester is suitable for the test of light fastness, weather fastness, light fastness and perspiration fastness to various colored textiles; it can also be used for the light fastness of paints, pigments, coatings, rubber, plastics, wood floors, paper and other materials Fastness test and light aging test.
Brand:
AVENOItem NO.:
AC02Payment:
T/T, L/CProduct Origin:
ChinaShipping Port:
Xiamen portLead Time:
7-10 daysApplication
Water-Cooled Light Weather Fastness Tester complies with AATCC TM16-2003 and GB/T8427-1998, GB/T8430-1998, GB/T14576-93, GB/T15102-2006, GB/T15104-2006, ISO 105 B02 and other related requirements. It is suitable for the test of light fastness, weather fastness, light fastness and perspiration fastness to various colored textiles; it can also be used for the light fastness of paints, pigments, coatings, rubber, plastics, wood floors, paper and other materials Fastness test and light aging test.
Standards
Model |
AC02 Water-Cooled Light Weather Fastness Tester |
Textile |
AATCC 169, GB/T 8430, GB/T 14576, GB/T 8427, ISO 105-B02/B04/B06, M&S C09 / C09A, JIS L0843 |
Rubber & Plastics |
GB/T 16422.1, GB/T 12831, GB/T9344, ASTM D2565, ISO 4892 |
Paint coating |
GB/T1865, ASTM D6695, ISO 11341, NES M0135 |
Non-metallic Material |
AATCC TM16, ASTM G26, ASTM D4459, ASTM G155, GB/T 2423.24, GB/T 15102, GB/T 15104 Car: SAE J2527, SAE J1885, SAE J2212, SAE J1960, SAE J2412, ISO3917, PV 1303, PV 3929, PV 3930, DVM 0067- MA HES D6601, TSL 0601G, GMW3414, EDS-T-7415, D47 1431 |
Dimension & Weight
Model |
AC02 Water-Cooled Light Weather Fastness Tester |
Dimensions |
120×90×180cm |
Weight |
350kg |
Key Specification
Model |
AC02 Water-Cooled Light Weather Fastness Tester |
Chamber temperature range |
30~90℃, ±0.1℃ |
Chamber humidity range |
Light cycle: 20~70RH%, ±0.1RH% Dark cycle: 30~95RH%, ±0.1RH% |
Test time range |
≤10000h |
Irradiance control range |
0.6~3.08W/m²@420nm, Option: 340nm, 300-400nm or 280-800nm Digital setting, automatic compensation |
Standard blackboard thermometer |
35~120℃, ±0.1℃ |
Xenon arc lamp rated power |
6kW |
Rotation speed of the sample frame |
3-7rpm, can be set |
Distribution diameter of sample clamp |
Φ550mm |
Sample holder |
AC02-1: ISO: 145×45mm 33pcs AATCC: 145×70mm 21pcs, option AC02-2: ISO: 145×45mm 48pcs AATCC: 145×70mm 36pcs, option |
Standard Accessories
Model |
AC02 Water-Cooled Light Weather Fastness Tester |
145*45mm sample holder for ISO and GB standard (AC02-1: 30pcs, AC02-2: 48pcs) |
1set |
45mm Cover plate (AC02-1: 1/2, 1/3, 2/3, each size30pcs) (AC02-2: 1/2, 1/3, 2/3, each size48pcs) |
1set |
145*70mm sample holder for AATCC standard (AC02-1: 21pcs, AC02-2: 36pcs) |
1set |
70mm Cover plate (AC02-1: 1/2, 1/3, each size21pcs) (AC02-2: 1/2, 1/3, each size36pcs) |
1set |
Sample board (AC02-1: ISO/GB 60pcs, AATCC 50pcs) (AC02-2: ISO/GB 100pcs, AATCC 80pcs) |
1set |
Oscillator for humidifier |
2pcs |
Xenon lamp water-cooled lamp holder (installed in main machine) |
1set |
Xenon arc lamp (1pc in main machine, 1pc spare) |
2pcs |
Standard blackboard thermometer |
1pc |
PP cotton (1pc in main machine, 1pc spare) |
2pcs |
Blue wool standard sample |
1set |
Grey scale |
1set |
Inner hexagon spanner |
1pc |
Fuse (5A) |
2pcs |
Drainage intake pipe |
1set |